Quick Switching Variables Sampling System Indexed by Six Sigma AQL and Six Sigma AOQL

Main Article Content

B. Esha Rae, D. Senthilkumar

Abstract

Quick Switching Sampling System was originally proposed by Dodge (1967) further Romboski (1969) studied the QSS-1
with the single sampling plan as a reference plan. Six Sigma Quick Switching Variables Sampling System, designated as
SSQSVSS (n; kT, kN) was studied by Senthilkumar and Esha rae (2012) and the probability of acceptance of the
lot is 1????3:410????6, where (n; kN) and (n; kT ), kT > kN are respectively the normal and tightened single sampling plans.
The method and procedure for designing the Six Sigma Quick Switching Variables Sampling System based on the given
Six Sigma Acceptable Quality Level and Six Sigma Limiting Quality Level. In this paper, the procedure and tables for
the selection of Six Sigma Quick Switching Variables Sampling System (SSQSVSS (n; kT, kN)) indexed by Six Sigma
AQL and Six Sigma AOQL are given, whenever rejected lots are 100% inspected for replacement of nonconforming units.
The tables are constructed for easy selection of the sampling system.

Article Details

How to Cite
B. Esha Rae, D. Senthilkumar (2022) “Quick Switching Variables Sampling System Indexed by Six Sigma AQL and Six Sigma AOQL”, International Journal of Current Research in Science and Technology, 3(10). doi: 10.57181/ijcrst.v3i10.17.
Section
Original Research Articles